Thursday, March 8, 2018
Never! Never! Never! use a tape product that is not designed specifically for your EPDM rubber roof on your RV. There are many different products that are sold to repair your RV roof but you should use only those that are made out of the same EPDM material. Remember that all EPDM roofing technology and repair procedures were developed by the commercial roofing manufactures. As we have stated previously, they are only two manufactures of this product in the U.S.: Carlisle Syntec Systems and Firestone Building Products. Their roofing systems have warranties up to thirty years on a roof. This is an extreme amount of time to be exposed to possible failures, so they do years of research and testing to make sure their products will perform. Never use any caulking that is not EPDM or butyl based.
Wednesday, February 28, 2018
How to Save Thousands on RV Roof Repairs
A brief history of RV roofing
Original RV roof, looking at the front
This article is not written to be a complete history of RV
roofing, but to give you an overview of what has happened over the last forty
years. In the early 1960s, most of the RV roofs were using a metal product to
make the roof water tight. Then, in the early 1980s, white EPDM roofing membrane
was introduced to this market. At the time there were only two manufactures of
this product in the U.S.: Carlisle and Colonial Rubber Works. I was an employee of Colonial Rubber Works at
that time, so I am more knowledgeable about their involvement in this market.
Colonial was looking for another market to sell their EPDM sheeting into, so they
started contacting RV manufactures about using their EPDM sheet on roofs of the
RVs being produced in the factory. The ability of EPDM roofing to withstand
outside weathering and UV light degradation made it one of the best roofs to
put on a flat roof surface.
Original RV roof, on the back
With this information, Colonial then sent salesmen to the
manufactures with the EPDM roofing product. The RV industry was very interested
in this product and its longevity on the roof. Since RV’s are produced in a
factory, the manufactures were very concerned about how quickly they could
install this product on a new roof and the cost. They were convinced this was a
superior product, but the determining factor would be how quickly it could be
installed in the manufacturing environment. They found out that this product
could be installed quickly and give the consumer a better product. At this time
Colonial provided a ten-year warranty on their white EPDM roofing while the
manufacturers usually gave a 5-year warranty to their customers. This EPDM
product was .045 mil thick and white. It quickly became the dominate roof in
the RV roofing industry.
Damaged roof, front of RV
Colonial continued testing the white EPDM membrane to make
sure the membrane would hold up long term on any flat roof. I worked in the research
and development (R&D) lab and tech service with the roofing division. One
of my jobs was to visit the job site when a customer had a complaint with
Colonial’s EPDM roofing. We found that even though EPDM is one of the best
rubbers for UV resistance, there were problems with the membrane after being
exposed on a roof after eight to fifteen years; this only occurred on the White
EPDM membrane. We found that white EPDM membrane would chalk and develop cracks
in the membrane after direct exposure to the sun. We cut samples and
examined them under a microscope and found out that some of these small cracks
would go deep enough into the membrane it could fail and leak. At that time, Colonial was only giving a ten-year warranty. In 1993 or 1994, Firestone bought
Colonial Rubber’s roofing plant in Kingstree, South Carolina. Since then, manufacturers have started making
their membrane half white and half black. This serves two purposes: if the
white cracks, the black will still be water tight and it cuts the cost since
white EPDM is more expensive.
Damaged roof, front of RV
EPDM white on black roofing dominated the market until a
couple of years ago when RV manufacturers started looking at cheaper roofing
products. Some of them replaced the .038 mil and .040 mil EPDM with a .030 mil
thick TPO. This product is extremely thin and will not hold up as a long-term roof.
This is not important to the RV manufacturers since they only warranty their
product for a limited time and most of the roofing problems won’t occur until
after the warranty period, so they are off the hook. This seems extremely short
sighted on their part since RVs cost thousands to hundreds of thousands of
dollars.
Applying the adhering membrane for the new roof, front of RV
You may wonder why I am writing this article or what is in
it for me, and that’s a good question. Yes, I have been involved in the do it
yourself (DIY) market for EPDM roofing and RV roofing since 1993. At that time, I formed my own company, AKT
Specialty. I do not sell any RV products direct to the manufacturers; I only
supply homeowners and RV owners with products to do their own repairs or
replacements. To be truthful, the moves that RV manufacturers made to be more
efficient and cut cost has been great for my business, but bad for consumers.
There are tens of thousands of RV roofs failing every year and we supply
consumers with RV roofing products for those repairs. I have owned five RVs and
I understand the frustration that comes when you pay $40,000+ for an RV and
have a roof leak within the first six years.
Applying metal bar to the front of the RV roof, on top of the rubber
There are a couple of
things that manufacturers of RVs can do that will save consumers millions of
dollars and cost them only fifty to a hundred dollars per unit, but they are
not willing to do it because roofing problems don’t show up big until the
warranty is expired. First, they can go
to a thicker membrane which would only cost a few more cents per square foot. Secondly,
they could add an eight-foot strip of EPDM cover tape on the front and back of
the RV where the metal is pulled up over the roof and fastened down with screws
and a metal bar. When this RV roof detail is installed at the factory, they use
a thick bead of caulk. In the roofing
industry, caulking is a temporary solution and not permanent like cover tape. Almost
all the leaks I have encountered with the RV roofs have been in this location.
Be sure you use an EPDM tape that has been designed by the manufacturer and
always prime the location where the tape is being applied; this will help it be
a permanent solution rather than just temporary. I would recommend taping these two areas
before leaks ruin the roof and cost thousands of dollars. I did some research
and found out that it costs from three to seven thousand dollars to replace
your RV roof.
Applying 6" tape over the metal bar on the front of the roof
I would like to warn you to be careful when ordering
replacement roofs for your RV. There are products out there that are only 8’6”
wide that are cheaper because of their width and thickness. The factory does
use this product, but their installation is done by professionals and they don’t
make mistakes during installation. I have personally installed these membranes
on damaged RV roofs and with this narrow 8’6” material, you have only an inch or
two to play with and if you’re over an inch you could not get a good seal around
your roof edge detail and that will result in a leak. If you have a mistake on the edge and you have
glued the membrane down, you have a terrible mess to correct. I recommend that you
always purchase a product at least a foot wider than you need, as this will save
time and money. Just remember, if you purchased a bullet proof vest, would you want one
that was thin or would you want the thicker one which would surely provide more protection? I hope
this information is helpful and I will try to provide some videos and pictures
that might help you. You can always contact Johnnie or Tim at www.flatroofsolutions.com and we will be glad
to discuss your needs or questions. Our toll free number is 1-866-630-7660.
Monday, March 4, 2013
Another rubber roofing product I would like to introduce to the public is the Firestone EPDM .090 mil roofing. Almost all epdm roofing products are either .045 or .060 mils thick. This membrane was designed to with stand more foot trafic and last a life time. It only comes in ten foot widths. It is an ideal product when installing a floating deck over a water proofing membrane. This product has also been used for many other uses. One of the more interesting one is for dog kennels. The membrane dosn't hurt the dog's feet and when they pee the pee doesn't soak into the concrete floor and have an odor. People also put this in the bottom of their horse trailers. You can purchase this membrane at flatroofsolutions.com. and justliners.com.
Thursday, February 21, 2013
Wow its been a year since I have posted information on my blog. I hope to do better in 2013. My interest has been in EPDM rubber roofing and EPDM pond liner. Most of my comments have been about the roofing side. I continue to be involved in projects dealing with this product. I have recently been to a couple of conventions dealing with epdm roofing and pond liners. The home pond liner market is dominated by epdm membrane. The most used one is Firestones PondGard epdm pond liner. There are a few very interesting things happening in the pond liner market. There are a lot of enviromental concerns present in the United States about water quality and water retention. So Fireston PondGard has spent a lot of time and money researching this market and developing products for it. One is called it's Epic system, this system uses liner, gravel, sand and pipe to convert a landscape or football field into a self-supporting system. The under ground liner holds the water to water the grass or landscape thus doing away with the need to water with sprinklers or hoses. This actually sotres your water on the premises. This systems are not cheap but they are working like they were designed to do. Most of these systems are being used commerically. I hope to give you more details about this system and pricing in the future. The other system Firestone is introducing is their Epic water garden kit. This kit is not your conventional water garden kit. We usually think about a water garden kit as being one that you have water and fish in. This new one is actually designed for the home gardener who rasies vegetables or flowers. This design is very exciteing and will help the homeowner to grow their own produce with-out the hassele of watering. This kit will be out sometime in March and I will let you know more about this product then. Both these products are available at justlilners.com. and flatroofsolutions.com.
Monday, January 9, 2012
We have finially started removing the old rubber membrane off of the camper. We found this to be very difficult because the old membrane was in so bad of shape it tore apart when trying to pull off. Once we removed the membrane we noticed that a lot of the wood decking had rotted and had to be replaced. The support rafters were still ok. On this install instead of removing all of the rotted board we covered it with new one quarter inch thick plywood. then screwed it into the rafters. We then cut all of our vent holes and cut a hole for the air-c0nditionare. We now had our Rv roof ready to install. We opened our box that contained our Roof-Top EPDM rubber membrane and carried it onto the RV roof. We unfolded the rubber roofing and completly covered the wood deck. We had about ten inches extra hanging over the edge, this was ok since we will trim the excess after the rubber membrane is glued down. After the rubber roofing was in place we folded it back in half over itself. We did this length wise not width. Always be carfull when doing this and avoid falling into the holes you have cut into your roof deck for your vents and air-conditionare. Once the membrane was folded back over itself we applied the glue onto the wood deck and membrane. We let dry to touch and then laid the membrane into the glue. Once this is done repeat the proceedure. The easiest way we found to lay the rubber roofing onto the deck was to get two ladders and put them on opposite sides of the RV. Then have a person on each ladder. Each person would grab the rubber roofing and pull into the glue. Try to stay to geather while doing this to keep from getting wrinkles in the roofing. This install went smooth and we are now ready to install the metal end pieces and the metal around the roof. Will do this later.
Tuesday, December 6, 2011
We have started removing the metal strip on the top side of the camper. This metal strip holds the roofing on the edges to the camper. We first removed the rubber gasket and then started removing the screws. However some of the screws stripped out and could not be unscrewed with a screw driver. We had to get a small blade and cut the screws into to remove. You may also have to use a pry bar to help with the removal of these screws. The metal strip on the top of the roof on the front of the camper was also removed. We had to cut the caulking off to remove these screws. We are now ready to remove all of the old roofing membrane. This will be difficult since the membrane is so deterioated that it is in pieces. We will let you know how this goes.
Tuesday, November 22, 2011
We have finially strated putting on a new roof on the RV that has been sitting here all fall. The first thing we removed off the old RV roof was the air-conditionare unit. You do this by removing the cover on the top of the air-conditionare. Then you go inside and take off inside cover and remove 4 bolts. This unataches the unit from the camper. You then unplug the wires and the unit is ready to lift off the roof. However on this unit we did have trouble getting it off. There is a foam gasket that attaches to the air-unit between the unit and the roof. On this seal silicone calk was also used. This make it very difficult when we tried to push the unit through the roof. We had to use pry bars to help lossen the seal. Once we broke the seal loose we removed the air-unit. We then started takeing off the vents. Each vent was fastened to the deck with screws going through the metal on the vent into the wood deck. It was then caulked over to prevent leaks. These also gave us a little trouble because of the extra caulking used during installation. We have already found bad deck board that will need to be replaced on the rv roof. We removed the other vents without any problems. We are ready now to remover the metal strip on the front of the trailer. Thats hold the rubber down to the deck. Should have more info tomorrow.
Subscribe to: