Thursday, July 18, 2019

In some of my past blog post I have written about how the RV Industry had changed the roofing membrane they were using on new RV roofs. For the last thirty years the RV industry were using an EPDM rubber roofing membrane to cover their roofs. It was originally .045 mil thick. This was the standard for most manufactures for most of these years. However the manufactures wanted a cheaper product so they put pressure on the suppliers for better prices. So Carlisle roofing systems and others started making their membrane .038 mils thick. This membrane also performed well and was used until the last five years. The EPDM rubber membrane has been a proven roof for over forty years. So the question why would the manufactures change the roofs they are putting on their new RVs when what they were using worked so well. I will give you the answer even though you already know. MONEY!!!!!!  Yes believe it or not MONEY!!!!. They will tell you that this new product is just as good as the EPDM membrane even though it is only .024 mill thick in most cases. Well I have been working in this industry for over thirty years and I can tell you that is a bunch of hog wash. Consumers are being sold new RVs that cost upwards of $100.000 that have these cheap roofs on them and many are failing within two years. I have personally tested many of these TPO .024 mill roofs and I can tell you, if you were able to conduct a couple of test yourself you would not buy an RV with this kind of roof on it. This .024 Mil thick TPO roofing membrane is usually has an textured surface so if you look at it under a microscope it is actually thinner. I am writing this article because recently I have had several people that live in my area  come to me complaining about the quality of their new RVs and especially the roof. They are looking for answers and are having a hard time getting their warrantee repairs don. Their many people who live in their RVs so they would have a difficult time having repairs or a new roof put on their RV.  So what is the answer, I am not sure but I will tell you their are many more people out there with RV problems. Be sure before you buy a new RV you get a written roof warrantee and know for  how long it will be covered  With all my experience in the roofing industry and research and developments lab I would never buy a new RV with a roofing membrane That's only .024 mill thick or less. If you have had problems your rv roofs or other things post it let people know.    

Thursday, September 27, 2018

EPDM Patches vs. TV Advertised Patches

We are comparing our EPDM Patches to the TV advertised patches. Want to see which ones holds up the best? Come back and see our results video later!

Wednesday, June 27, 2018

Repairing an RV Roof Skylight


Have any specific questions about RV roof repair or any questions? Let us know!

Tuesday, April 24, 2018

Monday, April 16, 2018

I would like to warn you to use extreme caution when ordering a replacement RV roof. There are products being sold in this market that would not be allowed on a commercial roof. Commercial roofing products are typically sold in .045 mil thickness and .060 mill thickness. They have a warranty of 10 to30 years and have over 40 years of performance testing on EPDM roofs. If this is the case for stationary commercial roofs, then why are replacement RV roofs being sold in .030 mil thickness? An RV is not stationary, and using thinner and improper material's will shorten the life of your RV roof.  

We need to remember that all RV rubber roofing technology originally came out of the commercial roofing market and their minimum standard for thickness for a commercial roof is .045 mil. So, now that you know more information, which would you choose: a thinner liner, or a thicker liner that is tested and proven with over forty years in the roofing industry?

Friday, April 6, 2018

We have been discussing different ways to save money when it comes to repairing or preventing leaks on your RV roof. If you have been trying to find something affordable to repair your roof with that you know will work, you're just in luck! Take a look at our Leak Prevention Kits, which comes in an Economy version and a Premium version. These kits come with just what you need to repair your leaky RV roof or to help prevent leaks from happening down the road. Take a look at the instructions below to see just how easy our kit is to use.

1. Thoroughly clean the detail of the roof that you are repairing with water and a mild detergent. Let the surface dry, then repeat the procedure with clean cloths until all the dirt and grime is removed. Allow the surface to dry completely.

2. Measure 4" from the center of the bar on each side and mark with a marker. These marks will show you where to apply your primer to ensure you have enough coverage for the tape.

3. Take your 2 ounce bottle of primer and shake thoroughly. While wearing gloves, apply primer to the marked area with the provided scrubber pad. Allow primer to dry. For best results, repeat primer application after the first layer of primer is dry. Be sure you apply primer on both sides of the bar, and anywhere you are going to be placing tape.

4. Position tape over the center of the bar and remove the backing paper. Apply the tape over the marked areas, trying to keep over the center of the bar. When you get to the end of the roof, cut off the excess tape and save it for future repairs you may have.

5. Once you have the tape applied, take your seam roller and roll over the tape to help ensure adhesion. Be sure to roll over the edges to make sure they are down.

6. After you have rolled over the tape, you can take the caulk and run a bead down the end of the tape. This is not necessary, but it does give you added protection. You can use the leftover caulk to go down the sides of the tape, too, but you may not have enough to cover the entire piece. You can always order an extra tube of caulk to give you some extra leak protection. 


The cured roofing tape in our Leak Prevention Kits is the same roofing tape that has been used in the roofing industry for the past 40 years. It is tried and true, so wouldn't you want to use something that you know has the reputation of being reliable? If you would like more information about our Leak Prevention Kits, you can visit our website at www.rv-roof-top.com and see what all is included. 







Friday, March 23, 2018

A popular repair on RV EPDM roofs is using coatings, which are supplied by many different manufactures. People think that using coatings to repair your roof is the easiest of all the repairs available. The instructions will start by telling you to thoroughly clean the membrane before you apply the product. Then you will need to measure out the area on the roof to be repaired; for example, you would measure out ten square feet, forty square feet, or one hundred square feet, depending on what you were repairing. They will tell you that one gallon of their product should cover a certain amount of square foot. Lets say, as an example, one gallon covers 100 square feet, .020 mil thick; when you finish applying one gallon, you should be around 100 square feet in coverage. You will use a squeegee or a paint roller to apply their product. So you have applied the product over the area you measured, and your bucket is empty; this means everything worked out as planned, right? Unfortunately, you do not know that for certain. How do you know if you have an equal coating over the entire roof? You could very easily have it thicker in some places than others; some places may have it .040 mil thick while others have only .010 mil thick. Even professionals have trouble being sure the coating is even over the entire roof. This is a major weakness when it comes to installing coatings over an existing roof. Fast forward to five years down the road, when you realize your roof is failing in certain areas. Say you have a warranty and the company asks for a sample; if the sample you send them is only .010 mil thick instead of the specified .020 mil thick, they will tell you that you have applied the coating wrong.

It would seem you are successful because you applied just the right amount of coating for the amount of square feet the instructions told you. But this would not be a true statement, because how would know that you had an equal amount of coating over all of this area? You could very easily have it .040 thick in places and as thin as .010 mill in others. There is no true way to gauge and install the same thickness all over the roof. Even professionals have trouble in making sure that you have met the minimum thickness requirements for the coating products. This is a major weak spot in installing coatings over any existing roof. If you have a warranty problem and they ask for a sample of the failed area and it is only .018 mil thick instead of the specified .020 mil thick they could deny your warranty claim.

This just goes to show you that the "easiest" solution is not always the best solution..


Thursday, March 8, 2018

Never! Never! Never! use a tape product that is not designed specifically for your EPDM rubber roof on your RV. There are many different products that are sold to repair your RV roof but you should use only those that are made out of the same EPDM material. Remember that all EPDM roofing  technology and repair procedures were developed by the commercial roofing manufactures. As we have stated previously, they are only two manufactures of this product in the U.S.: Carlisle Syntec Systems and Firestone Building Products. Their roofing systems have warranties up to thirty years on a roof. This is an extreme amount of time to be exposed to possible failures, so they do years of research and testing to make sure their products will perform. Never use any caulking that is not EPDM or butyl based.

Wednesday, February 28, 2018


How to Save Thousands on RV Roof Repairs
A brief history of RV roofing
Original RV roof, looking at the front

This article is not written to be a complete history of RV roofing, but to give you an overview of what has happened over the last forty years. In the early 1960s, most of the RV roofs were using a metal product to make the roof water tight. Then, in the early 1980s, white EPDM roofing membrane was introduced to this market. At the time there were only two manufactures of this product in the U.S.: Carlisle and Colonial Rubber Works.  I was an employee of Colonial Rubber Works at that time, so I am more knowledgeable about their involvement in this market. Colonial was looking for another market to sell their EPDM sheeting into, so they started contacting RV manufactures about using their EPDM sheet on roofs of the RVs being produced in the factory. The ability of EPDM roofing to withstand outside weathering and UV light degradation made it one of the best roofs to put on a flat roof surface.


Original RV roof, on the back


With this information, Colonial then sent salesmen to the manufactures with the EPDM roofing product. The RV industry was very interested in this product and its longevity on the roof. Since RV’s are produced in a factory, the manufactures were very concerned about how quickly they could install this product on a new roof and the cost. They were convinced this was a superior product, but the determining factor would be how quickly it could be installed in the manufacturing environment. They found out that this product could be installed quickly and give the consumer a better product. At this time Colonial provided a ten-year warranty on their white EPDM roofing while the manufacturers usually gave a 5-year warranty to their customers. This EPDM product was .045 mil thick and white. It quickly became the dominate roof in the RV roofing industry. 


Damaged roof, front of RV


Colonial continued testing the white EPDM membrane to make sure the membrane would hold up long term on any flat roof. I worked in the research and development (R&D) lab and tech service with the roofing division. One of my jobs was to visit the job site when a customer had a complaint with Colonial’s EPDM roofing. We found that even though EPDM is one of the best rubbers for UV resistance, there were problems with the membrane after being exposed on a roof after eight to fifteen years; this only occurred on the White EPDM membrane. We found that white EPDM membrane would chalk and develop cracks in the membrane after direct exposure to the sun. We cut samples and examined them under a microscope and found out that some of these small cracks would go deep enough into the membrane it could fail and leak. At that time, Colonial was only giving a ten-year warranty. In 1993 or 1994, Firestone bought Colonial Rubber’s roofing plant in Kingstree, South Carolina.  Since then, manufacturers have started making their membrane half white and half black. This serves two purposes: if the white cracks, the black will still be water tight and it cuts the cost since white EPDM is more expensive.


Damaged roof, front of RV


EPDM white on black roofing dominated the market until a couple of years ago when RV manufacturers started looking at cheaper roofing products. Some of them replaced the .038 mil and .040 mil EPDM with a .030 mil thick TPO. This product is extremely thin and will not hold up as a long-term roof. This is not important to the RV manufacturers since they only warranty their product for a limited time and most of the roofing problems won’t occur until after the warranty period, so they are off the hook. This seems extremely short sighted on their part since RVs cost thousands to hundreds of thousands of dollars.


Applying the adhering membrane for the new roof, front of RV


You may wonder why I am writing this article or what is in it for me, and that’s a good question. Yes, I have been involved in the do it yourself (DIY) market for EPDM roofing and RV roofing since 1993.  At that time, I formed my own company, AKT Specialty. I do not sell any RV products direct to the manufacturers; I only supply homeowners and RV owners with products to do their own repairs or replacements. To be truthful, the moves that RV manufacturers made to be more efficient and cut cost has been great for my business, but bad for consumers. There are tens of thousands of RV roofs failing every year and we supply consumers with RV roofing products for those repairs. I have owned five RVs and I understand the frustration that comes when you pay $40,000+ for an RV and have a roof leak within the first six years.


Applying metal bar to the front of the RV roof, on top of the rubber


There are a couple of things that manufacturers of RVs can do that will save consumers millions of dollars and cost them only fifty to a hundred dollars per unit, but they are not willing to do it because roofing problems don’t show up big until the warranty is expired.  First, they can go to a thicker membrane which would only cost a few more cents per square foot. Secondly, they could add an eight-foot strip of EPDM cover tape on the front and back of the RV where the metal is pulled up over the roof and fastened down with screws and a metal bar. When this RV roof detail is installed at the factory, they use a thick bead of caulk.  In the roofing industry, caulking is a temporary solution and not permanent like cover tape. Almost all the leaks I have encountered with the RV roofs have been in this location. Be sure you use an EPDM tape that has been designed by the manufacturer and always prime the location where the tape is being applied; this will help it be a permanent solution rather than just temporary.  I would recommend taping these two areas before leaks ruin the roof and cost thousands of dollars. I did some research and found out that it costs from three to seven thousand dollars to replace your RV roof.


Applying 6" tape over the metal bar on the front of the roof


I would like to warn you to be careful when ordering replacement roofs for your RV. There are products out there that are only 8’6” wide that are cheaper because of their width and thickness. The factory does use this product, but their installation is done by professionals and they don’t make mistakes during installation. I have personally installed these membranes on damaged RV roofs and with this narrow 8’6” material, you have only an inch or two to play with and if you’re over an inch you could not get a good seal around your roof edge detail and that will result in a leak. If you have a mistake on the edge and you have glued the membrane down, you have a terrible mess to correct. I recommend that you always purchase a product at least a foot wider than you need, as this will save time and money. Just remember, if you purchased a bullet proof vest, would you want one that was thin or would you want the thicker one which would surely provide more protection? I hope this information is helpful and I will try to provide some videos and pictures that might help you. You can always contact Johnnie or Tim at www.flatroofsolutions.com and we will be glad to discuss your needs or questions.  Our toll free number is 1-866-630-7660.





  

Monday, March 4, 2013

Another rubber roofing product I would like to introduce to the public is the Firestone EPDM .090 mil roofing. Almost all epdm roofing products are either .045 or .060 mils thick. This membrane was designed to with stand more foot trafic and last a life time. It only comes in ten foot widths. It is an ideal product when installing a floating deck over a water proofing membrane. This product has also been used for many other uses. One of the more interesting one is for dog kennels. The membrane dosn't hurt the dog's feet and when they pee the pee doesn't soak into the concrete floor and have an odor. People also put this in the bottom of their horse trailers. You can purchase this membrane at flatroofsolutions.com. and justliners.com.

Thursday, February 21, 2013

Wow its been a year since I have posted information on my blog. I hope to do better in 2013. My interest has been in EPDM rubber roofing and EPDM pond liner. Most of my comments have been about the roofing side. I continue to be involved in projects dealing with this product. I have recently been to a couple of conventions dealing with epdm roofing and pond liners.  The home pond liner market is dominated by epdm membrane. The most used one is Firestones PondGard epdm pond liner. There are a few very interesting things happening in the pond liner market. There are a lot of enviromental concerns present in the United States about water quality and water retention. So Fireston PondGard has spent a lot of time and money researching this market and developing products for it. One is called it's Epic system, this system uses liner, gravel, sand and pipe to convert a landscape or football field into a self-supporting system. The under ground liner holds the water to water the grass or landscape thus doing away with the need to water with sprinklers or hoses. This actually sotres your water on the premises. This systems are not cheap but they are working like they were designed to do. Most of these systems are being used commerically. I hope to give you more details about this system and pricing in the future. The other system Firestone is introducing is their Epic water garden kit. This kit is not your conventional water garden kit. We usually think about a water garden kit as being one that you have water and fish in. This new one is actually designed for the home gardener who rasies vegetables or flowers. This design is very exciteing and will help the homeowner to grow their own produce with-out the hassele of watering. This kit will be out sometime in March and I will let you know more about this product then. Both these products are available at justlilners.com. and flatroofsolutions.com.

Monday, January 9, 2012

We have finially started removing the old rubber membrane off of the camper. We found this to be very difficult because the old membrane was in so bad of shape it tore apart when trying to pull off. Once we removed the membrane we noticed that a lot of the wood decking had rotted and had to be replaced. The support rafters were still ok. On this install instead of removing all of the rotted board we covered it with new one quarter inch thick plywood. then screwed it into the rafters. We then cut all of our vent holes and cut a hole for the air-c0nditionare. We now had our Rv roof ready to install. We opened our box that contained our Roof-Top EPDM rubber membrane and carried it onto the RV roof. We unfolded the rubber roofing and completly covered the wood deck. We had about ten inches extra hanging over the edge, this was ok since we will trim the excess after the rubber membrane is glued down. After the rubber roofing was in place we folded it back in half over itself. We did this length wise not width. Always be carfull when doing this and avoid falling into the holes you have cut into your roof deck for your vents and air-conditionare. Once the membrane was folded back over itself we applied the glue onto the wood deck and membrane. We let dry to touch and then laid the membrane into the glue. Once this is done repeat the proceedure. The easiest way we found to lay the rubber roofing onto the deck was to get two ladders and put them on opposite sides of the RV. Then have a person on each ladder. Each person would grab the rubber roofing and pull into the glue. Try to stay to geather while doing this to keep from getting wrinkles in the roofing. This install went smooth and we are now ready to install the metal end pieces and the metal around the roof. Will do this later.

Tuesday, December 6, 2011

We have started removing the metal strip on the top side of the camper. This metal strip holds the roofing on the edges to the camper. We first removed the rubber gasket and then started removing the screws. However some of the screws stripped out and could not be unscrewed with a screw driver. We had to get a small blade and cut the screws into to remove. You may also have to use a pry bar to help with the removal of these screws. The metal strip on the top of the roof on the front of the camper was also removed. We had to cut the caulking off to remove these screws. We are now ready to remove all of the old roofing membrane. This will be difficult since the membrane is so deterioated that it is in pieces. We will let you know how this goes.

Tuesday, November 22, 2011

We have finially strated putting on a new roof on the RV that has been sitting here all fall. The first thing we removed off the old RV roof was the air-conditionare unit. You do this by removing the cover on the top of the air-conditionare. Then you go inside and take off inside cover and remove 4 bolts. This unataches the unit from the camper. You then unplug the wires and the unit is ready to lift off the roof. However on this unit we did have trouble getting it off. There is a foam gasket that attaches to the air-unit between the unit and the roof. On this seal silicone calk was also used. This make it very difficult when we tried to push the unit through the roof. We had to use pry bars to help lossen the seal. Once we broke the seal loose we removed the air-unit. We then started takeing off the vents. Each vent was fastened to the deck with screws going through the metal on the vent into the wood deck. It was then caulked over to prevent leaks. These also gave us a little trouble because of the extra caulking used during installation. We have already found bad deck board that will need to be replaced on the rv roof. We removed the other vents without any problems. We are ready now to remover the metal strip on the front of the trailer. Thats hold the rubber down to the deck. Should have more info tomorrow.

Thursday, October 27, 2011

repair rv roof

I was up at the lake winterizing our 36 foot montana camper yesterday and when I got up on the roof to sweep off the leaves, I noticed that where the front roof joined the metal there was a crack in the caulking. This is exactly the area we have talked about in the past. The EPDM rubber roof was glued down to the trailer and the metal was brought over the top and screwed down with a metal bar and then caulk was applied to seal the screws and metal bar. We have discussed before that this is a bad design. The factory could have used 6" cover tape during the original installation and I would not have had roofing problems. All I had with me was a tube of caulk, so I washed the area throughly and applied the caulk. However this is only a tempory repair. Next I am up I will install a new 6" cover strip of tape to make a perment repair. I will finially start the roof replacement on this RV camper. We will be putting a new RV rubber roof on this camper and taking pictures of it.

Thursday, October 6, 2011

rv roof repairs

We are just about ready to start our replacement on our RV rubber roof. This epdm rubber roof was leaking in several places. The worst was on the front where the metal joined the rubber roof. This area is usually one of the first places your RV rubber roof will leak. Sometimes you can just repair this area and not have to replace your entire roof. On one of my campers I had to repair this area and the camper was only seven years old. To make a permant repair on this area, I first cleaned with water. I changed rags constantly because the rags were dirty, not with dirt but with a chalk substance comming from the rubber roof. So be sure to keep using clean rags. If you do not clean this area enough your repair tape will not stick correctly. Once you have cleaned the epdm roofing membrane you need to apply a tape primer activator to the roof and the metal where the roof joins. Once you have coated this area with primer let dry then do it again. Then using 6" wide epdm cover tape put three inches on the metal and three on the rubber roof. Then roll with a roller the tape into the primer. This will make a permanent repair. I have been busy the last few weeks and it looks like it will now be the last of October before we do the RV roof replacement.

Thursday, September 29, 2011

roofing maintance continued

The last time we talked about rv roofing maintance we discussed why you should wash or not wash your roof. A lot of people in the RV industry tell you to wash your roof yearly and use a coating on your roof. This practice did not come directly from the manufactures. In a commerical application you would simply install the white on black EPDM membrane and leave it alone. Sure you might do a yearly inspection to look for holes or problems, but I can assure you they would never recomend that you wash your roof . This roofing product is made to withstand UV sunlight and exposure to the outside elements. A big concern I have about dealers recommending that roofs be cleaned yearly, is that a large percentage of RV owners are elderly and anytime that you work on a roof, there is a danger of falling. We need to remember the EPDM white on black roofing was designed to be a low maintance product. I own two different RVs with EPDM white on black roofing on them one is 14 years old and the other is 7 years old. I have never washed either roof and they are left outside all of the time. Rember once you start coating a roof it turns into an ongoing project. This could also prove costly over several years.